Air to air vertical shock chambers ShockEvent T
ShockEvent T is a dual-chamber vertical shock test chamber. The hot chamber (top) and cold chamber (below) are arranged on top of each other.
ShockEvent T is a dual-chamber vertical shock test chamber. The hot chamber (top) and cold chamber (below) are arranged on top of each other. It compresses the “transfer zone” between the cold and hot zones with a transfer time. The test specimen moves between these two chambers in a basket, secured with protection grids. The weisstechnik vertical shock chambers allow the performance of endurance tests of over 1000 cycles without defrosting.
This makes the ShockEvent T unique.
- Protect your valuable test material: Triple test material fuse included as standard. Active test items can be deenergized via a potential-free contact. Test chamber can switch off in the event of a fault in the test material or be set to a defined value (optional).
- Flexibility and a wide range of standards: The vertical shock test chambers comply with a wide range of international testing standards (including MIL-STD 810, MIL-STD 883, IEC 60068-2-14, and JESD22-A101-A) and offer over 30 different options, making them versatile enough to meet the testing needs of a wide variety of industries and applications.
- User-Friendliness and Connectivity: A color touchscreen display with intuitive menu navigation tailored to the vertical shock test chambers, along with the optional SIMPATI® software, enables easy programming, remote monitoring, and network connectivity.
- Maximum reliability and reproducibility: Precise temperature control and fast transfer times (10–12 seconds) ensure reproducible test results, reliable detection of quality defects, and accurate service life predictions.
- Exceptionally high load-bearing capacity and durability: The test chambers are designed to accommodate test specimens weighing up to 100 kg in the lifting basket and to perform more than 1,000 cycles without defrosting. This ensures low maintenance requirements, longer operating times, and maximum operational reliability.
- Energy Efficiency and Sustainability: Energy-saving mode and excellent insulation reduce energy consumption, cut operating costs by up to 40%, and significantly lower CO₂ emissions compared to conventional solutions.
How the vertical shock test chamber works
The ShockEvent T air-to-air vertical shock test chambers are equipped with two separate temperature chambers, a hot and a cold chamber. A test specimen basket is mounted on a vertical lift between the two zones. This type of construction is called the “elevator type”.
Each zone is permanently and independently set to its target temperature. The test specimen moves vertically in a basket from the hot zone to the cold zone or vice versa. As a result, it is exposed to an extreme temperature change within seconds. The test specimen remains in the zone until its core temperature reaches the required stability. This usually takes between 10 and 30 minutes.
We develop the optimal solution for your application.
The ShockEvent T is ideal for conducting common thermal shock test standards. In single-chamber operation, it works like a classic temperature test chamber and therefore also be used for selected cold tests.
Cold tests
Shock operation
ETSI EN 300019-2-4, Test Ab/Ad
MIL-STD 883L Meth. 1010.9, severity level A,B,C,D,F
MIL-STD 810H, Meth. 502.5
MIL-STD 810H Meth. 503.7
JEDEC JESD22-A119
IEC 60068-2-14 Na
IEC 60068-2-1, Test A (LV 124 K-03)
Normal operation – precision and compliance standards.
In normal operation, the ShockEvent T works according to classic test principles and is therefore the preferred choice for standard-compliant and reproducible temperature change tests. The chambers are precisely set to the target temperatures. After transfer to the respective chamber, the test specimen is subjected to a defined holding time. During this time, the temperature is continuously monitored to ensure that the test conditions meet the specifications. This mode is particularly suitable when the test temperatures are close to the maximum or minimum specification values for the test specimen or when high precision and comparability of results are required. Normal operation ensures reliable compliance with standards such as IEC 60068-2-14 and is ideal for quality-critical validations and certifications.
Time-optimized operation – Efficient test cycles for maximum productivity.
Time-optimized operation of the ShockEvent T is specially designed to significantly accelerate test cycles and increase efficiency in the testing laboratory. In this mode, temperatures in the hot and cold chambers are deliberately increased or lowered beyond the target values, so that the test specimen reaches the required temperature more rapidly after transfer. The holding time can be shortened, since the test specimen stays longer in the target temperature range and the temperature is within the tolerance more quickly. This allows for significant time savings per cycle and makes it ideal for applications with high throughput or tight time frames. Time-optimized operation is particularly relevant for serial testing in which speed is paramount but without compromising on testing quality.
Energy-saving operation – sustainable efficiency and maximum cost savings.
The ShockEvent T is equipped with the innovative GreenMode as standard. This intelligent energy-saving mode was specially developed for demanding thermal cycling tests. Thanks to smart controls, optimized components and intelligent software, the GreenMode reduces energy consumption by up to 32% depending on the test time and at the same time ensures cost savings of up to 40%. At the same time, testing quality is fully maintained – a real advantage for energy- and cost-conscious companies.
In addition, users benefit from reduced cooling water consumption, lower grid load, lower noise emissions and sustainable reductions in CO₂.
Options
- LN2 shock cooling: Additional cooling for connection to an LN 2 supply on the customer’s premises to support cold shocking.
- Emergency-stop button on test space housing: The emergency stop button is installed on the outside of the test chamber, at the height of the door lock. When actuated, a message is displayed on the control panel and the test is stopped.
- Fault message to potential-free switching contact: If a fault occurs at the test chamber, a potential-free switching contact is actuated.
- Temperature measurement on the test specimen: Up to five movable Pt100 temperature sensors with flexible cable enable temperature measurement in the basket or on the test specimen.
- Temperature measurement on the test specimen using the NiCrNi sheath thermocouple: Movable temperature sensor as Ni-Cr-Ni thermocouple with flexible cable for temperature measurement anywhere in the test space or on the test specimen. The flexible cable length is approx. 5m and the sensor is 3m in length.
- Temperature measurement on the test specimen via NiCrNi thermocouple wire: Movable temperature sensor as Ni-Cr-Ni thermocouple wire, welded measuring tips, with a flexible cable for temperature measurement anywhere in the test space or on the test specimen. The flexible cable length is approx. 5 m.
- Temperature measurement on the test specimen by thermocouple can be switched to a lifting basket control sensor: The switch takes place via a digital switching channel. The measured value is displayed in the control unit and can be called up via the interfaces.
- Temperature measurement on the test specimen via transmitter using a NiCrNi thermocouple: Movable temperature sensor as Ni-Cr-Ni thermocouple with flexible cable for temperature measurement anywhere in the test space or on the test specimen.
- Analog measured value card: There are 5 outputs 0 to 10 V and 4 inputs for Pt 100 available for the processing and output of analogue measuring signals.
- Analogue measured value card: 5 outputs 0 to 10 V and 4 inputs for Ni-Cr-Ni thermocouple type K are available for the processing and output of analogue measurement signals.
- Transfer time, variable: A variable transfer time has the advantage that the stress can be dosed for the test specimen. This is required if the devices are to be used for screening applications. - Selection between 5 levels - Length of time at each level can be selected from 3 seconds to 120 seconds.
- Extended temperature range in the hot chamber of up to +250°C: The temperature range is extended to +250°C.
- Energy meter direct up to 63 A: One total and one program energy meter- also in connection with data acquisition via the optional Software S!MPATI®.
- Hose kit for cooling water network 3/4", 2x2.5m, flexible: For connection to a cooling water network, two flexible hoses with a connection of G ¾” and a length of 2.5 m are provided.
- Hose kit for cooling water network 3/4", 2x5m, flexible: For connection to a cooling water network, two flexible hoses with a connection of G ¾” and a length of 5 m are provided.
- Insulation of water inlet at a water flow of <+12 °C: Cooling water hoses in the test chamber are additionally insulated.
- Electronic cooling water controller: Automatic adaptation to different flow temperatures and pressure differences is achieved within certain limits by means of an electronically operated and continuously controlled valve.
- Refrigerant pipe, 2-fold: Extension to a total distance of 3 m. Flexible refrigerant pipes are installed between the external condenser and the test chamber.
- Refrigerant pipe, 2-fold: Extension to a total distance of 5 m. Flexible refrigerant pipes are installed between the external condenser and the test chamber.
- GN2 / Compressed air connection: Connection with coupling plug DN 7.2 for operation with the customer’s compressed air dryer or for the injection of an inert gas into the hot and cold chamber. The function can be enabled/disabled on the control unit or via the S!MPATI® software.
- Electric door tumbler, normally closed (NC): The test space door cannot be opened during testing, in the event of a power failure and when the main switch is powered off. The test space door is unlocked at the end of a test and when a test is stopped. The same applies to a pause and in the event of a malfunction when the temperature is switched off.
- Electric door tumbler, normally closed (NC): The test space door is unlocked at the end of a test and when a test is stopped, in the event of a power failure and when the main switch is powered off. The same applies to a pause and in the event of a malfunction when the temperature is switched off.
Available models
- ShockEvent T/60/V2
- ShockEvent T/120/V2
- ShockEvent T/120/V2/32
- ShockEvent T/120/V2/P
- ShockEvent T/300/V2
- ShockEvent T/300/V2/P
La fel la toate modelele
- Temperature recovery time:
- 15 min
- Temperature range hot chamber:
- 50 ... 220 °C
- Temperature range cold chamber:
- -80 ... 100 °C
Transfer time between cold and hot chamber2 valori
- 10 s
- ShockEvent T/60/V2, ShockEvent T/120/V2, ShockEvent T/120/V2/32, ShockEvent T/120/V2/P
- 12 s
- ShockEvent T/300/V2, ShockEvent T/300/V2/P
Testspace volume3 valori
- 60 l
- ShockEvent T/60/V2
- 120 l
- ShockEvent T/120/V2, ShockEvent T/120/V2/32, ShockEvent T/120/V2/P
- 300 l
- ShockEvent T/300/V2, ShockEvent T/300/V2/P
Test Space Dimensions (H x W x D)3 valori
- 370 × 380 × 430 mm
- ShockEvent T/60/V2
- 410 × 470 × 650 mm
- ShockEvent T/120/V2, ShockEvent T/120/V2/32, ShockEvent T/120/V2/P
- 610 × 770 × 650 mm
- ShockEvent T/300/V2, ShockEvent T/300/V2/P
External Dimensions (HxWxD)4 valori
- 2330 × 900 × 2150 mm
- ShockEvent T/60/V2
- 2450 × 1000 × 2530 mm
- ShockEvent T/120/V2, ShockEvent T/120/V2/32
- 2450 × 1000 × 2805 mm
- ShockEvent T/120/V2/P
- 2900 × 1320 × 2380 mm
- ShockEvent T/300/V2, ShockEvent T/300/V2/P
Sound Pressure Level4 valori
- 58 dB(A)
- ShockEvent T/60/V2, ShockEvent T/300/V2
- 59 dB(A)
- ShockEvent T/120/V2, ShockEvent T/120/V2/32
- 69 dB(A)
- ShockEvent T/120/V2/P
- 72 dB(A)
- ShockEvent T/300/V2/P
| Specificație | ShockEvent T/60/V2 | ShockEvent T/120/V2 | ShockEvent T/120/V2/32 | ShockEvent T/120/V2/P | ShockEvent T/300/V2 | ShockEvent T/300/V2/P |
|---|---|---|---|---|---|---|
| Transfer time between cold and hot chamber | 10 s | 12 s | ||||
| Temperature recovery time | 15 min | |||||
| Testspace volume | 60 l | 120 l | 300 l | |||
| Test Space Dimensions (H x W x D) | 370 × 380 × 430 mm | 410 × 470 × 650 mm | 610 × 770 × 650 mm | |||
| External Dimensions (HxWxD) | 2330 × 900 × 2150 mm | 2450 × 1000 × 2530 mm | 2450 × 1000 × 2805 mm | 2900 × 1320 × 2380 mm | ||
| Sound Pressure Level | 58 dB(A) | 59 dB(A) | 69 dB(A) | 58 dB(A) | 72 dB(A) | |
| Temperature range hot chamber | 50 ... 220 °C | |||||
| Temperature range cold chamber | -80 ... 100 °C | |||||
Valoare comună modelelor peste care se întinde