Atmosfär test chambers
Atmosfär chambers are designed for fully automatic testing to the demanding laboratory-accelerated corrosion tests that have become increasingly popular in the automotive industry.
Atmosfär chambers have been specifically designed for fully automatic testing in accordance with highly demanding laboratory-accelerated corrosion tests which have become increasingly popular in some sectors of the automotive industry. These tests are cyclic in nature and comprise of exposure under controlled and varying conditions of temperature and humidity, with intermittent spraying of a salt solution directly on to the samples under test, from a high level swaying spray bar.
This makes the Atmosfär unique.
- CO2 Cooling: Now also available with CO2 Cooling according to EU F-GAS regulation 2024/573
- Oscillating spray bar: Oscillating spray bar with magnetically coupled drive system, for compliance with the most demanding automotive test standards.
- Smart Control System: 7" color touchscreen with intuitive interface. Storage for up to 254 complex test programs. Remote access via LAN for monitoring and data logging and is compatible with control software S!MPATI from Weiss Technik
- Different cooling units from Ambient control: An option of different cooling units from Ambient control (Lite Model) to sub zero at -20 or -40 °C. Water cooled options are also available for sub cooling units where room heat dissipation is an issue.
- Psychrometric humidity control: Psychrometric humidity control, for more exacting control of humidity, especially at levels around 94% RH.
- Ergonomic design: Low loading threshold for easy loading and unloading.
Atmosfär Modes of Operation.
Atmosfär Chamber control system gives incredible flexibility. Not only can the customer comply with a large number of different, less demanding Cyclic Corrosion Test Standard specifications, but can also comply with the most demanding of corrosion tests, particularly as used in the automotive industry, from OEMs such as Ford, Volvo, Scania, and others. The chambers temperature and humidity control can also be further extended upon with the wide range of accessories that may be added.
Our range of standard cyclic chambers come with the ability to create 6 distinct functions to create the most common corrosive environment: Salt Spray Fog, Condensation Humidity (wetting), Forced Air Drying, Controlled Humidity (see adjacent graph), Ambient Drying, Temperature Control only
The Atmosfär range also adds.
A range of 3 Sub cooling units
Lite Version down to 20 °C
Sub Zero version down to -20 °C
Sub Zero version down to -40 °C
Cooling units also available with F-Gas regulation compliant CO2
Oscillating Vertical spray down swaying bar with uniform fallout with patented Mag-Drive technology
Psychrometric control of humidity for more exacting control of humidity, required for levels around 95%RH
Uniform airflow from above.
A very high standard of temperature uniformity.
Additional scope for other Test Standard requirements can also be fulfilled because of the wide range of optional accessories that are available, which further extend the number of climates and conditions that can be created. See below for standard operation as well as just a few of the additional accessories that expand the range.
Popular Atmosfär Test Standards.
FORD CETP00.00-L-467
ISO 16701
Scania STD 4319
Scania STD 4445
TPJLR.52.265
Volvo STD 1027,1375
Volvo STD 1027,14
Volvo STD 423-0014
Volvo STD 4233
Plus many more – please note some of the above will require accessories to be included in the configuration.
Installation requirements.
Water: The air saturator, humidity generator and salt solution reservoir all require separate connections to a continuous, pressurized deionized/distilled water supply of 2.5–5.0 bar (36–73 psi). If ACC42 is ordered the continuous water supply must be pressurized 4.0 – 5.0 bar (58-72 psi).
Air: Clean dry & oil free compressed air, 4.0 to 6.0 bar (58-87psi) with 440 Ltrs (15.5cu.ft) per minute flow. Two separate supplies are required, one for the chamber and one for the separate refrigeration unit.
Exhaust: 3m (10ft) exhaust pipe is required which should be terminated outside building (see accessory ACC58).
Drain: 3m (10ft) drain pipe is required which should be terminated into floor level drain (see accessory ACC58).
Operating environment conditions: Indoors, with ambient maintained at +18 to +23 °C (+64 to 73 °F), 85% max RH (non-condensing).
Options
- Wall Wash System (ACC42): This option comprises of a water spray system to automatically wash the walls with water for a user adjustable number of minutes, at programmable points within a corrosion test cycle. This is required for some automotive standards such as Renault D17 2028 or RNES-G-00005 or ECC-1. It is also used when rapid cooling is required for JASO M 609, CCT-1, IEC 60068-2-52 and many other test standards.
- Heater Blower System (ACC47): The blower heater assists in increasing and decreasing the chamber temperature and also decreasing humidity process values, which is a requirement of test standards such as JASO M609, CCT-1, and IEC 60068-2-52. This is achieved by introducing ambient air from the local area in which the equipment is located by means of a forced air blower and ball valve. Two alternatives are available: Rapid to 70°C and Ultra-Rapid to 80°C.
- Additional atomisers (ACC25): Additional salt spray atomiser(s) and associated pump(s) fitted to the chamber, to generate higher fall-out rates of 2.0 to 5.5ml/80cm²/hour, which is required during the salt spray phase of test standards VDA 233-102, Renault D17 2028 (ECC1), SAE J 2334 Method C and RNES-G-00005.
- Immersion Facility (ACC34): Under programmed control, heated immersion liquid (usually salt water heated to a user adjustable temperature up to +50°C/+122°F) is automatically pumped from the holding tank into the chamber, immersing the test samples. The liquid is automatically returned to the holding tank at the end of the immersion period. Immersion is a requirement of standards Hyundai CCT-C, CCT-D, Honda 5100Z & ASTM G44.
Available models
- AT1300iP/13
- AT1300iP/14
- AT1300iP/15
- AT1300iP/16
- AT1300iP/17
- AT2600iP/13
- AT2600iP/14
- AT2600iP/15
- AT2600iP/16
- AT2600iP/17
La fel la toate modelele
- Salt Solution Reservoirs:
- 90 l (conventional atomiser) and 160 l (oscillating spray bar)
- Oscillating salt spray:
- ambient … +60 °C, 5 … 10 l/m² per hour
- Wetting mode:
- ambient … +70 °C, 95 … 100 % RH
- Forced air drying:
- ambient … +70 °C
- Electricity supply:
- two 3-phase supplies (chamber and air-conditioning unit)
Version3 valori
- Lite
- AT1300iP/15, AT2600iP/15
- -20 °C
- AT1300iP/13, AT1300iP/16, AT2600iP/13, AT2600iP/16
- -40 °C
- AT1300iP/14, AT1300iP/17, AT2600iP/14, AT2600iP/17
Cooling2 valori
- CO₂, air-cooled
- AT1300iP/15, AT1300iP/13, AT1300iP/14, AT2600iP/15, AT2600iP/13, AT2600iP/14
- CO₂, water-cooled
- AT1300iP/16, AT1300iP/17, AT2600iP/16, AT2600iP/17
Minimum Controlled Temperature3 valori
- +20 °C
- AT1300iP/15, AT2600iP/15
- -20 °C
- AT1300iP/13, AT1300iP/16, AT2600iP/13, AT2600iP/16
- -40 °C
- AT1300iP/14, AT1300iP/17, AT2600iP/14, AT2600iP/17
Testspace volume2 valori
- 1300 l
- AT1300iP/15, AT1300iP/13, AT1300iP/14, AT1300iP/16, AT1300iP/17
- 2600 l
- AT2600iP/15, AT2600iP/13, AT2600iP/14, AT2600iP/16, AT2600iP/17
Test Space Dimensions (H x W x D)3 valori
- 1080 × 1520 × 928 mm
- AT1300iP/15, AT2600iP/15
- 1500 × 1300 × 980 mm
- AT1300iP/13, AT1300iP/14, AT1300iP/16, AT1300iP/17
- 1500 × 2160 × 980 mm
- AT2600iP/13, AT2600iP/14, AT2600iP/16, AT2600iP/17
External Dimensions (H x W x D)2 valori
- 1965 × 2025 × 1316 mm
- AT1300iP/15, AT1300iP/13, AT1300iP/14, AT1300iP/16, AT1300iP/17
- 1965 × 2885 × 1316 mm
- AT2600iP/15, AT2600iP/13, AT2600iP/14, AT2600iP/16, AT2600iP/17
Refrigeration unit dimensions (H x W x D)2 valori
- 1070 × 650 × 1350 mm
- AT1300iP/15, AT2600iP/15
- 1624 × 1125 × 1354 mm
- AT1300iP/13, AT1300iP/14, AT1300iP/16, AT1300iP/17, AT2600iP/13, AT2600iP/14, AT2600iP/16, AT2600iP/17
Total Weight2 valori
- 340 kg
- AT1300iP/15, AT1300iP/13, AT1300iP/14, AT1300iP/16, AT1300iP/17
- 440 kg
- AT2600iP/15, AT2600iP/13, AT2600iP/14, AT2600iP/16, AT2600iP/17
Power Rating2 valori
- 4.9 kW
- AT1300iP/15, AT1300iP/13, AT1300iP/14, AT1300iP/16, AT1300iP/17
- 7.7 kW
- AT2600iP/15, AT2600iP/13, AT2600iP/14, AT2600iP/16, AT2600iP/17
| Specificație | AT1300iP/15 | AT1300iP/13 | AT1300iP/14 | AT1300iP/16 | AT1300iP/17 | AT2600iP/15 | AT2600iP/13 | AT2600iP/14 | AT2600iP/16 | AT2600iP/17 |
|---|---|---|---|---|---|---|---|---|---|---|
| Version | Lite | -20 °C | -40 °C | -20 °C | -40 °C | Lite | -20 °C | -40 °C | -20 °C | -40 °C |
| Cooling | CO₂, air-cooled | CO₂, water-cooled | CO₂, air-cooled | CO₂, water-cooled | ||||||
| Minimum Controlled Temperature | +20 °C | -20 °C | -40 °C | -20 °C | -40 °C | +20 °C | -20 °C | -40 °C | -20 °C | -40 °C |
| Testspace volume | 1300 l | 2600 l | ||||||||
| Test Space Dimensions (H x W x D) | 1080 × 1520 × 928 mm | 1500 × 1300 × 980 mm | 1080 × 1520 × 928 mm | 1500 × 2160 × 980 mm | ||||||
| External Dimensions (H x W x D) | 1965 × 2025 × 1316 mm | 1965 × 2885 × 1316 mm | ||||||||
| Refrigeration unit dimensions (H x W x D) | 1070 × 650 × 1350 mm | 1624 × 1125 × 1354 mm | 1070 × 650 × 1350 mm | 1624 × 1125 × 1354 mm | ||||||
| Total Weight | 340 kg | 440 kg | ||||||||
| Power Rating | 4.9 kW | 7.7 kW | ||||||||
| Salt Solution Reservoirs | 90 l (conventional atomiser) and 160 l (oscillating spray bar) | |||||||||
| Oscillating salt spray | ambient … +60 °C, 5 … 10 l/m² per hour | |||||||||
| Wetting mode | ambient … +70 °C, 95 … 100 % RH | |||||||||
| Forced air drying | ambient … +70 °C | |||||||||
| Electricity supply | two 3-phase supplies (chamber and air-conditioning unit) | |||||||||
Valoare comună modelelor peste care se întinde