Sari la conținut
Bumbas Electric

AtmosfärPremium test chamber1 / 6

AtmosfärPremium test chamber

AtmosfärPremium test chamber

Atmosfär Premium chambers offer the widest test-standard scope of the Atmosfär range, with increased temperature ranges and faster temperature transitions for demanding automotive corrosion tests.

Atmosfär chambers have been specifically designed for fully automatic testing in accordance with highly demanding laboratory-accelerated corrosion tests which have become increasingly popular in some sectors of the automotive industry. These tests are cyclic in nature and comprise of exposure under controlled and varying conditions of temperature and humidity, with intermittent spraying of a salt solution directly on to the samples under test, from a high level swaying spray bar.

The Premium version of the Atmosfär Range offers the most extensive and flexible Test Standard scope solution on the market place with increased temperature ranges and faster temperature transition times.

This makes the Atmosfär Premium unique.

  • CO2 Cooling: Now also available with CO2 Cooling according to EU F-GAS regulation 2024/573
  • Oscillating spray bar: Oscillating spray bar with magnetically coupled drive system, for compliance with the most demanding automotive test standards.
  • Smart Control System: 7" color touchscreen with intuitive interface. Storage for up to 254 complex test programs. Remote access via LAN for monitoring and data logging and is compatible with control software S!MPATI from Weiss Technik
  • Different cooling units from Ambient control: An option of different cooling units from Ambient control (Lite Model) to sub zero at -20 or -40 °C. Water cooled options are also available for sub cooling units where room heat dissipation is an issue.
  • Psychrometric humidity control: Psychrometric humidity control, for more exacting control of humidity, especially at levels around 94% RH.
  • Widest application for test norms: The Atmosfar premium range fulfils the widest range of test standards on the market
  • Vertical airflow: Pre-conditioned air from the separate air conditioning unit, is delivered to the chamber and passes vertically and evenly though the test samples, evenly,- from top to bottom during the climate controlled testing phase

Atmosfär Modes of Operation.

The AtmosfärPremium control system has the widest temperature and humidity envelope in the Ascott chamber range. Not only can the chamber comply with a large number of different less demanding Cyclic and Salt Spray test standard specifications such as, ASTM, Renault’s ECC1, JASO & VDA but can also comply with environmental temperature & humidity testing required by Volkswagen PV 1200 & PV 1209. Making the AtmosfärPremium chamber truly without equal in the world of corrosion testing.

Our range of standard cyclic chambers come with the ability to create 6 distinct functions to create the most common corrosive environments.

Test chamber performance.

Temperature Range

Humidity Range

Salt Spray Fallout rates

Wetting Mode

Ambient to +70 °C

95% - 100% RH

N/A

Oscillating Salt Spray Mode

Ambient to +60 °C

5 to 10 l/m²/h

Dual Atomiser Salt Spray Mode

0.5 to 5.5 ml

per 80cm²/h

Drying Mode

Ambient to +80 °C

Uncontrolled

Climatic Mode

See adjacent graph

Ambient Air Drying Mode

Alters to laboratory ambient conditions

Popular Atmosfär Test Standards.

FORD CETP00.00-L-467

ISO 16701

Scania STD 4319

Scania STD 4445

TPJLR.52.265

Volvo STD 1027,1375

Volvo STD 1027,14

Volvo STD 423-0014

Volvo STD 4233

Plus many more – please note some of the above will require accessories to be included in the configuration.

Typical modes and transitions that can be achieved.

35 °C Salt Spray (100% RH) to 70 °C Air Drying < 30 min. (required by Hyundai CCT-B)

70 °C Air drying to 50 °C >95% RH < 20min. (required by Hyundai CCT-B)

50 °C >95% RH to Salt Spray 35 °C (100% RH) < 30 min. (required by Hyundai CCT-B, CCT 1, CCT 2, JASO M609, JASO M610)

60 °C Air Drying to -20 °C < 60 min.

80 °C / 80% RH Controlled Humidity to -40 °C Freezing in 120 min. (required by VW PV1200 & VW PV1209)

Extra scope for other Test Standard requirements can also be fulfilled because of our wide range of optional accessories that are available which further extend the number of climates and conditions that can be created. See below for standard operation as well as just a few of the additional accessories that expands the range.

Installation requirements

Water: Deionized/distilled for topping up air saturator and making salt solution. The continuous water supply must be pressurized 4.0 – 5.0 bar (58-72 psi). If air saturator is intended to be topped up manually option ACC66 must be ordered.

Air: Clean dry and oil free compressed air, 4.0 to 6.0 bar (58-87psi) with 440 l (15.5cu.ft) per minute flow. Two separate supplies are required, one for the chamber and one for the separate refrigeration unit.

Exhaust: 3m (10ft) exhaust pipe is required which should be terminated outside building (see accessory ACC58).

Drain: 3m (10ft) drain pipe is required which should be terminated into floor level drain (see accessory ACC58).

Operating environment conditions: Indoors, with ambient maintained at +18 to +23 °C (+64 to 73 °F), 85% max RH (non-condensing).

Options

  • Liquid Immersion (ACC34): Under programmed control, heated immersion liquid (usually salt water heated to a user adjustable temperature up to +50°C/+122°F) is automatically pumped from the holding tank into the chamber, immersing the test samples. The liquid is automatically returned to the holding tank at the end of the immersion period. Immersion is a requirement of standards Hyundai CCT-C, CCT-D, Honda 5100Z & ASTM G44.
  • Exhaust Scrubber Unit (ACC92): Designed to remove highly corrosive salt fog from the chamber exhaust, in chamber installations where it is either not convenient or not possible to allow the chamber exhaust to ventilate freely to atmospheric pressure outside the building.
  • User Programmable Output Signal (ACC78): This option enables the chamber user to have their own remote electrical equipment switched on/off at user programmable times, during a running test program. The output is provided via a voltage free change over contact (3A rated at 30VDC/250VAC) terminated at a chamber mounted 3-pin plug and socket for the user to wire to. Maximum of 4 can be fit to the chamber.
  • Water Fog Humidity (ACC32): This option provides a second solution line, independent pumping and delivery system and additional reservoir. It is most commonly used with water to create high humidity conditions (95 -100% RH) by spraying water as a fog, this is a requirement of some standards such as SAE J 2334, GMW 14872 & GMW9540.

Available models

  • AT1300iP/18
  • AT1300iP/21
  • AT1300iP/19
  • AT1300iP/22
  • AT1300iP/20
  • AT2600iP/18
  • AT2600iP/21
  • AT2600iP/19
  • AT2600iP/22
  • AT2600iP/20