Sari la conținut
Bumbas Electric

Compact temperature test chamber LabEvent1 / 5

Compact temperature test chamber LabEvent

Compact temperature test chamber LabEvent

On a footprint of around 1.4m², the compact LabEvent temperature test chamber takes care of temperature testing for batteries and electronic components. This 2m-tall LabEvent has a test chamber volume of 580 liters.

On a footprint of around 1.4m², the compact LabEvent temperature test chamber takes care of temperature testing for batteries and electronic components. This 2m-tall LabEvent has a test chamber volume of 580 liters. Installation is flexible and simple, since the device is operated via a conventional 230V electrical outlet.

That makes the LabEvent 500 unique.

  • Minimal installation site requirements: Our component test chambers do not require compressed air for dehumidification, and thanks to the large tank, even long climate test cycles can be carried out without a permanent water connection.
  • High-precision absolute humidity control: For the most demanding climate cycling tests.
  • Also available for minimal requirements: A reduced version with lower investment costs is available for low requirements (e.g. a constant temperature of 25 °C).
  • Wide range of connectivity options: The chamber can be controlled via a wide variety of interfaces. Our own SimServ interface and OPC-UA are available, as well as various bus systems such as PROFIBUS, PROFINET or EtherCAT. In this respect, it is in no way inferior to its larger counterpart, the TempEvent reach-in temperature test chamber.
  • Multi-level test specimen protection: Dual software protection plus additional hardware-based test specimen protection with an independent temperature sensor.
  • Optimized for limited space: The chamber is specially optimized for smaller test specimens and limited space. 580 liters of test space with a minimal footprint of < 1.5 m².

The perfect partner for stress tests in the field of batteries.

The compact LabEvent-model temperature test chamber implements standardized temperature tests for stress tests in battery applications. This includes the requirements in accordance with UN 38.3 which ensure that lithium-ion batteries and cells do not pose a hazard when transported. For this purpose, the batteries undergo numerous test cycles. The chamber also complies with the ESA 100 standard, suitable for battery engineers and manufacturers for the validation of market readiness, as well as the DIN EN 60068-2-14 specification, which involves testing rapid changes in ambient temperature – a standard task for the system. The test chamber can also be integrated into existing test bench systems via an interface.

The LabEvent 500 can accommodate up to 180 battery cells, but at the same time has the smallest footprint of all comparable devices. Inserts in standard euro dimensions in a special rack allow 1,000 loading/unloading circuits simultaneously. These testing chambers are to be used at a renowned laboratory to build an automated test bench for cell characterization. The goal is the so-called “electronic cell passport”, which will allow device manufacturers to compare the aging profiles of different cells from different manufacturers.

Hazard Level equipment for consistently safe testing.

The LabEvent 500 chambers can be optionally equipped with Hazard Levels 0 to 6. They are available as lithium-ion test chambers up to HL 6.

¬ Specialized safety equipment for the testing of lithium-ion batteries

¬ Full connectivity with cycler and BMS on request

¬ Available as a constant temperature test chamber down to -10°C, with CO2 down to -50°C and with F-gases down to -60°C.

Also available with climate add-on.

The versions with CO2 down to -50°C and F-gas down to -60°C are available as climate versions. Constant climate tests as well as selected climate change tests such as IEC 60068-2-30 are possible. For this purpose, the chamber is fitted with a steam humidifier and a dehumidification cooling system or a compressed air dryer (depending on the customer’s requirements and infrastructure).

¬ Humidity values of 10% to 98% RH possible

¬ Flexible dehumidification via compressed air or dehumidification cooling

¬ Meets constant climate requirements

¬ Meets selected climate change tests such as IEC 60068-2-30

Options

  • Additional Access Ports: Access port made of stainless steel, available in three standard sizes Ø 50, 80, 125 mm, including 1 silicone plug closed and 1 foam + silicone plug, slotted.
  • Access port, nominal width 50 mm: Access port Ø 50 mm incl. 1 closed silicone plug and 1 slotted silicone foam plug.
  • Access port, nominal width 80 mm: Access port Ø 80 mm incl. 1 closed silicone plug and 1 slotted silicone foam plug.
  • Access port, nominal width 125 mm: Access port Ø 125 mm incl. 1 closed silicone plug and 1 slotted silicone foam plug.
  • Access port in the ceiling, nominal width 50 mm: The access port (D1) Ø 50 mm is located in the ceiling according to the installation plan, incl. 1 closed silicone plug.
  • Access port in the ceiling, nominal width 80 mm: The access port (D1) Ø 80 mm is located in the ceiling according to the installation plan, incl. 1 closed silicone plug.
  • Access port in the ceiling, nominal width 125 mm: The access port (D1) Ø 125 mm is located in the ceiling according to the installation plan, incl. 1 closed silicone plug.
  • Foam silicone plug, nominal width 80 mm, 1 x slotted: Suitable for an access port with a nominal diameter of 80 mm. The silicone foam plug Ø 87 x 40 mm is provided with a slot. Cables and measuring leads can be inserted into this slot.
  • Foam silicone plug, nominal width 125 mm, 1 x slotted: Suitable for an access port with a nominal diameter of 125 mm. The silicone foam plug Ø 132 x 40 mm is provided with a slot. Cables and measuring leads can be inserted into this slot.
  • Foam silicone plug, nominal width 50 mm, 1 x slotted: Suitable for an access port with a nominal diameter of 50 mm. The silicone foam plug Ø 56 x 40 mm is provided with a slot. Cables and measuring leads can be inserted into this slot.
  • Drawer on telescopic rail: The pull-out drawer on telescopic rails can be positioned at different heights in the adjustment rails mounted on the sides.
  • Shelf, distributes load max. 100 kg: Reinforced stainless steel shelf for accommodating a customer-supplied test rig with test specimens. The maximum load capacity is 100 kg per square metre. The shelf can be fitted and removed at any time.
  • Shelf: Stainless steel shelves can be placed on the supplied support rails for holding test specimens. Maximum load per shelf: 20 kg uniformly distributed load.
  • Increased temperature change rate: Fitting an additional heater increases the rate of temperature change in heating mode to 6 K/min.
  • Mobile version: Six steering castors are mounted. The standard cabinet height is increased by 50 mm.
  • Door with window: Multi-insulated, heated viewing window in the door. (Format: 520 mm x 418 mm)
  • Door hinged on the right: The test space door will be hinged on the right hand side of the test cabinet. Door lock and operating panel will be positioned on the left hand side.
  • Test chamber activation via digital input for ≥ 3 K
  • Extension for climate operation mode: Modifications to the unit make it possible to carry out climate test runs. Control is provided by a capacitive measurement system.
  • GN2/Compressed air connection: For operation with a customer-provided compressed air dryer or for the supply of an inert gas. The function can be activated/deactivated via the control panel or the S!MPATI® software. The installation room must be well ventilated during operation with GN2; otherwise, there is a risk of suffocation.
  • Compressed air dryer for dew points to -30 °C uncontrolled: Dehumidification unit for dew points down to -30 °C (uncontrolled operation) to prevent condensation on the test specimens during temperature tests. The unit is switched on or off via a digital switching channel. The unit is self-regenerating.
  • Temperature measurement on test specimen: Movable temperature sensor Pt 100 with flexible cable for temperature measurement at any point in the test room or on the test object. The measured value is displayed in °C on the control panel and can be called up via the interfaces or the free analogue outputs of the measured value card.
  • Temperature measurement on the test specimen: Many norms, such as the new version of IEC 60068-2-14 Nb, require close observation and recording of the temperature of the test specimen during the test phases. Our test chamber can be equipped with additional temperature sensors, the values from which are displayed and recorded on the display (via USB or with S!MPATI®). One of the sensors can also be used as a control sensor if required.
  • Temperature measurement on test specimen (max. 1 sensor) switchable as control sensor: The changeover is via a digital switch channel. The measured value is displayed on the control unit and can be called up via the interfaces. The sensor is inserted into the test space via the standard port.
  • Temperature measurement on the test specimen using the NiCrNi sheath thermocouple: Movable temperature sensor as Ni-Cr-Ni thermocouple with flexible cable for temperature measurement anywhere in the test space or on the test specimen. The flexible cable length is approx. 5m and the sensor is 3m in length.
  • Temperature measurement on the test specimen via NiCrNi thermocouple wire: Movable temperature sensor as Ni-Cr-Ni thermocouple wire, welded measuring tips, with a flexible cable for temperature measurement anywhere in the test space or on the test specimen. The flexible cable length is approx. 5 m.
  • Temperature measurement at the test specimen by means of thermocouple Ni-Cr-Ni, switchable as control sensor: The switchover is via digital switch channel. The measured value is displayed on the control unit and can be called up via the interfaces.
  • Temperature measurement on the test specimen via transmitter using a NiCrNi thermocouple: Movable temperature sensor as Ni-Cr-Ni thermocouple with flexible cable for temperature measurement anywhere in the test space or on the test specimen.
  • Analog measured value card: There are 5 outputs 0 to 10 V and 4 inputs for Pt 100 available for the processing and output of analogue measuring signals.
  • Analogue measured value card: 5 outputs 0 to 10 V and 4 inputs for Ni-Cr-Ni thermocouple type K are available for the processing and output of analogue measurement signals.
  • Hose kit for cooling water network 3/4", 2x2.5m, flexible: For connection to a cooling water network, two flexible hoses with a connection of G ¾” and a length of 2.5 m are provided.
  • Hose kit for cooling water network 3/4", 2x5m, flexible: For connection to a cooling water network, two flexible hoses with a connection of G ¾” and a length of 5 m are provided.
  • Insulation of water inlet at a water flow of <+12 °C: Cooling water hoses in the test chamber are additionally insulated.
  • Special voltage on request: Special voltage on request
  • Adaptation to Bosch regulations for standard and modified standard units: The adaptation includes the use of the main switch as an EMERGENCY STOP button, the attachment of various information signs, the attachment of a protective cover, and 1 program CD with contents: SIMCON/32-BIN / S!MPAC data backup and UTD/UpToDate3.exe.

Available models

  • LabEvent T/500/50/3 (CO2)
  • LabEvent T/500/60/3