Mobile stability test container
With the PharmaEvent mobile stability test containers, you not only gain flexibility but also remain consistently uncompromising.
Act flexibly and expand capacities
With the PharmaEvent mobile stability test containers, you not only gain flexibility but also remain consistently uncompromising. The comprehensive GMP-compliant basic equipment is the ideal basis for high-precision stability tests, and the wide range of options allow you to customize the equipment to your specific needs.
Overview
Compliant testing. Act flexibly. Simply safe operation.
The stability test containers reliably fulfill GMP requirements and ICH guideline Q1A for the stability testing of active pharmaceutical ingredients and medicinal products. All ICH climates are possible. We offer you the optional S!MPATI® pharma software package for seamlessly secure documentation of storage in accordance with FDA 21 CFR Part 11 and EU GMP Annex 11.
As a long-standing specialist in climate testing systems, Weiss Pharmatechnik has developed control and operating solutions with which climate values can be set with high precision and the systems can be operated conveniently. PharmaEvent uses the tried-and-tested S!MPAC® control system and the GMP-compliant WEBSeason® pharma control panel with audit trail.
Stability testing, easier and safer than ever
- Plug & Play: ready for use immediately after power connection
- Absolute homogeneity thanks to ideal air flow – even with loaded systems
- Energy-efficient design thanks to double insulation
- GMP-compliant user management with audit trail and alarm system according to GAMP
- Operation from the workstation without additional software using the integrated WEBSeason®
- Multilingual operation
- Connection to the Simpati Pharma monitoring system; can also be integrated into LIMS systems
Functionality
It couldn’t be simpler. The extremely accurate and reliable PharmaEvent stability test containers can be validated and are specially designed to enable you to comply with the requirements of ICH guideline Q1A. The system is available in two test space sizes of 18 and 47 m³.
All you need is an installation place with a suitable power connection. The mobile climate container has a full-grade climate chamber for high-precision temperature and humidity tests, a tempered lock, a recirculating air system, and a control cabinet with the necessary switching and control devices.
La fel la toate modelele
- Dimensions of lock, W × H × D:
- 2060 × 2310 × 1600 mm
- Water tank:
- 100 l
- Temperature range:
- +20 to +45 °C
- Temperature deviation, in time:
- ±0.1 to ±0.5 K
- Temperature homogeneity, in space (IEC 60068-3-5):
- ±0.5 to ±1.0 K
- Dew point temperature range:
- +9 to +41 °C
- Humidity range:
- 20 to 80 % RH
- Humidity deviation:
- ±1 to ±3 % RH
- Nominal voltage:
- 3/N/PE AC 400 V ±10 %, 50 Hz
- Nominal power:
- 12 kW
Container outer dimensions, W × H × D2 valori
- 2438 × 2896 × 6058 mm
- C 18'
- 2438 × 2896 × 12192 mm
- C 47'
Test chamber volume [m³]2 valori
- 18
- C 18'
- 47
- C 47'
Dimensions of test chamber, W × H × D2 valori
- 2060 × 2310 × 3980 mm
- C 18'
- 2060 × 2310 × 10080 mm
- C 47'
Weight2 valori
- 4150 kg
- C 18'
- 6890 kg
- C 47'
| Specificație | C 18' | C 47' |
|---|---|---|
| Container outer dimensions, W × H × D | 2438 × 2896 × 6058 mm | 2438 × 2896 × 12192 mm |
| Test chamber volume [m³] | 18 | 47 |
| Dimensions of test chamber, W × H × D | 2060 × 2310 × 3980 mm | 2060 × 2310 × 10080 mm |
| Weight | 4150 kg | 6890 kg |
| Dimensions of lock, W × H × D | 2060 × 2310 × 1600 mm | |
| Water tank | 100 l | |
| Temperature range | +20 to +45 °C | |
| Temperature deviation, in time | ±0.1 to ±0.5 K | |
| Temperature homogeneity, in space (IEC 60068-3-5) | ±0.5 to ±1.0 K | |
| Dew point temperature range | +9 to +41 °C | |
| Humidity range | 20 to 80 % RH | |
| Humidity deviation | ±1 to ±3 % RH | |
| Nominal voltage | 3/N/PE AC 400 V ±10 %, 50 Hz | |
| Nominal power | 12 kW | |
Valoare comună modelelor peste care se întinde