Temperature and climatic test chambers up to 25 K/min TempEvent
Our stress screening test chambers, TempEvent model, feature high rates of temperature change, from 10 to 25 K/min.
Our stress screening test chambers, TempEvent model, feature high rates of temperature change, from 10 to 25 K/min. They are ideal for ageing tests as well as for electrically operated test specimens with high heat loads (e.g. 8000 W at 20°C) and heavy test specimens (of up to 500 kg). For these challenges, in particular, where standard solutions quickly reach their limits, our temperature and climatic test chambers are designed for rapid thermal cycling tests.
This is what makes our stress screening test chambers unique.
- For AI and electronics with high waste heat: With heat compensation of 8000 W at 20°C, for example, our test chambers are best suited for testing high-performance hardware such as CPUs, GPUs or TPUs. Even in the case of intensive waste heat from the test specimen, they ensure stable test conditions and reliable results, even under extreme loads.
- Requirements from the defence sector: Heavy loads meet dynamics: our test chambers enable the testing of heavy test specimens weighing up to 500 kg without compromising on the temperature change rate. This allows you to test even high-mass components under realistic, dynamic conditions.
- Protect your valuable test material: Triple test material fuse included as standard. Active test items can be deenergized via a potential-free contact. Test chamber can switch off in the event of a fault in the test material or be set to a defined value (optional).
- Efficiency meets performance: Despite their high performance, our test chambers are equipped with the intelligent GreenMode. This enables a significant reduction in energy consumption and thus also in the total cost of ownership (TCO). For sustainable testing processes without compromising performance.
- Networked. Flexible. Future-proof: Our test chambers can be seamlessly integrated using our SIMPATI software and interfaces such as SimServ, LabVIEW, OPC UA, PROFIBUS, PROFINET or EtherCAT. SECS/GEM is available for the semiconductor industry; ASCII continues to be available as before.
- Environmentally friendly cooling with CO₂: Where -50°C is sufficient, we offer our high-performance test chambers with the natural refrigerant CO₂ (GWP = 1) on request. This has clear advantages: lower electricity costs, no expenditure for leak testing, and quieter operation. A sustainable solution that pays off.
Environmental stress screening – at top speed to assured quality.
During the ESS test, the test specimens are subjected to precisely pre-defined stress in order to detect defects in components and circuit boards early enough. Finding weaknesses significantly improves the robustness of the products.
The environmental stress screening (ESS) of test specimens is achieved by means of thermal stress with rapid changes in temperature. ESS is the most effective method of detecting poor joint soldering and SMD processes as well as defects in components and errors in production, in good time before delivery.
Our ESS chambers achieve these results thanks to the heating and cooling capacities as well as the circulating air volumes being significantly higher than in conventional test chambers.
Ready for the latest in high-performance hardware.
Practically every device has a chip in it. From sensors in cars to LED lights for minimally invasive surgery – we need to and must be able to rely on the quality and function of all components under all conditions. Every day, everywhere and in every weather.
Our test chambers compensate for up to 8000W of waste heat at 20°C – ideal for testing GPUs, TPUs and other AI components. The SECS/GEM interface means that the systems can be integrated seamlessly into your manufacturing environment.
Available as an option: ESD protection for sensitive electronics and nitrogen flushing to reliably prevent corrosion on contacts.
Defence testing: test safely – also under extreme conditions:
Thanks to the optional ATEX equipment and robust heavy-duty rails (500 kg – more on request), our stress screening cabinets can be adapted precisely to individual requirements. Sufficient cooling capacity is reliably available, even at temperatures of -55°C.
Insufficient test space? With the flexibly expandable test chamber extension, existing chambers can be easily adapted to new or larger test requirements.
Efficiency meets performance with the GreenMode
Our test chambers only deliver as much power as is actually required. The integrated GreenMode not only reduces energy consumption and electricity costs, but also minimises compressor wear and tear.
For large test room sizes, we take things one step further with GreenMode+: an additional, third compressor takes over when cooling requirements are low, e.g. during temperature runs – for maximum efficiency and a longer service life of the main compressors. This option is installed as standard in temperature chambers with test chamber volumes of 800 litres and more.
An investment in your future and in your environment goals.
Taking a test chamber with a volume of 270 litres and 15 K/min at -5°C as an example, you can save up to 50 kWh (87 kWh with Greenmode instead of 137 kWh without Greenmode) of electricity within 24 hours and thus up to €400 in electricity costs per month.
Options
- Expansion of the test chamber for climate mode: Our stress screening test chambers are available with precise humidity control and a humidity range of 10 to 98% RH. Perfect partner for demanding climatic tests that have to be carried out in accordance with international standards. Supported standards include: IEC 60068-2-30, Test Db, variants 1 and 2; IEC 60068-2-38; MIL-STD-810H, Method 507.5; JESD22-A100D
- Additional Access Ports: Access port made of stainless steel, available in three standard sizes Ø 50, 80, 125 mm, including 1 silicone plug closed and 1 foam + silicone plug, slotted.
- Heavy-load rails: This option includes a modification of the test space and the exterior housing. Via special rails, the test specimen load is transferred from the test space to the exterior housing. Depending on the size, the surface load is up to 350 kg or 500 kg. The test space height is reduced by 5°mm.
- Web panel below the door lock: The operating/programming and monitoring unit with a 25.4 cm (10") web panel is mounted below the door lock.
- Webpanel installed at any location on side wall: The operating/programming and monitoring unit with 25.4cm (10") web panel can be mounted anywhere on the side panel. (The exact positioning must be specified when ordering)
- Demineralization unit, 10 l, pressure-proof to 6 bar: If no demineralized water is available from the customer, a demineralization unit can be connected upstream. ( Replacement cartridge available)
- Activated carbon filter for demineralized water: Fitting located behind the lifting gear. The standard access port (Ø 80 mm) remains installed.
- Access port in the ceiling: Access port in the ceiling made of stainless steel, available in three standard sizes Ø 50, 80, 125 mm.
- Lead-through pad, incl. replacement insert: The installation is located behind the lifting gear. The standard feedthrough, Ø 80 mm, stays installed.
- Notched access port welded: A welded notch bushing measuring approx. 50 mm x 50 mm is fitted in the housing cover on the right for inserting cables. This allows test material to be inserted without having to remove cables and lines.
- Disconnection of fan via digital channel: Disconnection of the fan is activated and deactivated via a digital channel on the control panel. If the digital channel “disconnection of fan” is activated, the fan and the temperature-conditioning unit are switched off immediately.
- Window in the door: Multi-insulated, heated viewing window in the door. (Format: 520 mm x 418 mm)
- Switchable privacy screen for test specimens: You want to protect your test specimen comfortably from prying eyes? The window pane of the test chamber can be made opaque by means of a digital switching channel via the light switch. (Only in connection with the “window in the door” option)
- Door hinged on the right: Version of the device door with door hinge on the right side. The notched port option is not possible. The flat notch port option is possible at the top left.
- Door seals can be replaced for tests with hydraulic oil: Hydraulic oil places special demands on the seals. They have to be replaced more often. The seals are mounted on the door to make them easier to replace.
- Test chamber activation via digital input: The test can only be started if a voltage signal of +24 V DC max. 30 mA is present at the digital input or if the adapter plug has been plugged into the 25-pin D-Sub socket “Digital I/O”.
- Emergency-stop button on test space housing: The emergency stop button is installed on the outside of the test chamber, at the height of the door lock. When actuated, a message is displayed on the control panel and the test is stopped.
- Signal lamp, two colours: The two-colour signal lamp installed on top of the test chamber indicates the operating mode.
- Fault message to potential-free switching contact: If a fault occurs at the test chamber, a potential-free switching contact is actuated.
- Door contact switch for “Door open” notification on the control unit / S!MPATI®: The components of the door contact switch are mounted on the test chamber and on the test chamber door. Monitoring of the test space door is activated when the test starts. When the test space door is opened, the message “Door open” appears on the control panel.
- Safety interlock switch, open at zero current: The components of the electrical door interlock are mounted on the test chamber and on the test chamber door. The monitoring of the test chamber door is activated when the test is started.
- Safety interlock switch, closed at zero current: The components of the electrical door lock are mounted on the test chamber and test chamber door. The control system for the test chamber door will be activated when starting the test.
- Extension of climate range with compressed air: With the optional “capacitive humidity measuring system” (mat. no. 64624928) controlled operation with a dew point down to -20 °C is possible if compressed air is provided by the customer.
- Unregulated compressed air dryer for dew points down to -30 °C: Dehumidification equipment for dew points down to -30 °C (unregulated operation) to prevent condensation on the test specimen during temperature tests. Activation and deactivation are controlled via a digital switching channel. For climate test chambers, regulated operation is possible up to a dew point of -12 °C.
- Compressed air dryer for dew points down to -20 °C controlled / down to -30 °C uncontrolled: Dehumidification device for Climate Test Chambers including a capacitive humidity measuring system for dew points down to -20 °C (controlled operation). Controlled dehumidification is started by activating the dehumidification device via a digital switch channel. It can also be used as a dehumidification device for dew points down to -30 °C (uncontrolled operation) to avoid condensation formation on the test specimen during temperature tests.
- GN2 / Compressed air connection: Connection with coupling plug DN 7.2 for operation with the customer’s compressed air dryer or for the injection of an inert gas into the hot and cold chamber. The function can be enabled/disabled on the control unit or via the S!MPATI® software.
- Additional humidity control with capacitive humidity measuring system: In addition to the standard-issue psychrometric measuring device, a capacitive humidity measuring system is also installed. Humidity control is enabled either via this humidity sensor or the psychrometric measuring device.
- Independent humidity measuring sensor for reference measurement: Capacitive sensor for humidity measurement and sensor for temperature measurement, located in the supply air next to the control sensor. This option is used for reference measurement, as the measured values are recorded independently of the unit control.
- Temperature measurement on the test specimen: Many norms, such as the new version of IEC 60068-2-14 Nb, require close observation and recording of the temperature of the test specimen during the test phases. Our test chamber can be equipped with additional temperature sensors, the values from which are displayed and recorded on the display (via USB or with S!MPATI®). One of the sensors can also be used as a control sensor if required.
- Temperature measurement on test specimen (max. 1 sensor) switchable as control sensor: The changeover is via a digital switch channel. The measured value is displayed on the control unit and can be called up via the interfaces. The sensor is inserted into the test space via the standard port.
- Temperature measurement on test specimen: Movable temperature sensor Pt 100 with flexible cable for temperature measurement at any point in the test room or on the test object. The measured value is displayed in °C on the control panel and can be called up via the interfaces or the free analogue outputs of the measured value card.
- Temperature measurement on the test specimen using the NiCrNi sheath thermocouple: Movable temperature sensor as Ni-Cr-Ni thermocouple with flexible cable for temperature measurement anywhere in the test space or on the test specimen. The flexible cable length is approx. 5m and the sensor is 3m in length.
- Temperature measurement on the test specimen via NiCrNi thermocouple wire: Movable temperature sensor as Ni-Cr-Ni thermocouple wire, welded measuring tips, with a flexible cable for temperature measurement anywhere in the test space or on the test specimen. The flexible cable length is approx. 5 m.
- Temperature measurement at the test specimen by means of thermocouple Ni-Cr-Ni, switchable as control sensor: The switchover is via digital switch channel. The measured value is displayed on the control unit and can be called up via the interfaces.
- Temperature measurement on the test specimen via transmitter using a NiCrNi thermocouple: Movable temperature sensor as Ni-Cr-Ni thermocouple with flexible cable for temperature measurement anywhere in the test space or on the test specimen.
- Additional 4 Digital I/O: 4 digital outputs for controlling the additional functions via the potential-free contacts, load max. 24 V-DC, 0.5 A, 4 digital inputs can be queried via interface, load max. 24 V-DC, approx. 30 mA
- Analogue measuring card: 5 outputs 0 to 10 V and 4 inputs for Pt 100 are available for processing and output of analog measuring signals.
- Analogue measured value card: 5 outputs 0 to 10 V and 4 inputs for Ni-Cr-Ni thermocouple type K are available for the processing and output of analogue measurement signals.
- Energy meter: Professional energy analysis with an energy meter
- Air- or water-cooled: Many test chambers are available as air- or water-cooled and can be supplied according to your infrastructure. Water cooling is available for all systems and, for more powerful test chambers, it often makes more sense to dissipate the waste heat via a cooling water connection. Air-cooled versions are to be discussed on an individual basis on request.
- Supply connections installed at the top: The following supply connections are mounted on the top: Cooling water connection including optional insulation of water supply. Supply of demineralized water (Climate Test Chambers only) Compressed air supply (available as additional equipment)
- Hose kit for cooling water network 3/4", 2x2.5m, flexible: For connection to a cooling water network, two flexible hoses with a connection of G ¾” and a length of 2.5 m are provided.
- Hose kit for cooling water network 3/4", 2x5m, flexible: For connection to a cooling water network, two flexible hoses with a connection of G ¾” and a length of 5 m are provided.
- Hose set for cooling water network 1", 2x2.5m, flexible: For connection to a cooling water network, two flexible hoses with a G 1" connection and a length of 2.5 m are supplied.
- Hose set for cooling water network 1", 2x5m, flexible: For connection to a cooling water network, two flexible hoses with a G 1" connection and a length of 5 m are supplied.
- Insulation of water inlet at a water flow of <+12 °C: Cooling water hoses in the test chamber are additionally insulated.
- Pump system for floors without drain: The integrated pump-down system pumps the water in the system (condensate, humidification water, cleaning water) against the gradient into a drain on the customer side
- Special voltage on request: Special voltage on request
- Water Cooling CO2
Available models
- T/270/70/10-25
- T/480/70/11-25
- T/800/70/10-25
- T/1300/70/10-25
La fel la toate modelele
- Voltage Rating:
- 3/N/PE AC 400 V ±10 % 50 Hz
- Refrigerant (main/pre-cooling):
- R449A / R23 (R469A)
- Temperature range:
- -70 … 180 °C
- Range for temperature change rate:
- 10 ... 25 K/min
Testspace volume4 valori
- 268 l
- T/270/70/10-25
- 494 l
- T/480/70/11-25
- 836 l
- T/800/70/10-25
- 1385 l
- T/1300/70/10-25
Test Space Dimensions (H x W x D)4 valori
- 750 × 580 × 615 mm
- T/270/70/10-25
- 950 × 800 × 650 mm
- T/480/70/11-25
- 950 × 1100 × 800 mm
- T/800/70/10-25
- 950 × 1100 × 1325 mm
- T/1300/70/10-25
External Dimensions (HxWxD)4 valori
- 1950 × 895 × 2322 mm
- T/270/70/10-25
- 2090 × 1115 × 2605 mm
- T/480/70/11-25
- 2118 × 1415 × 2810 mm
- T/800/70/10-25
- 2118 × 1415 × 3335 mm
- T/1300/70/10-25
Total load3 valori
- 140 kg
- T/270/70/10-25
- 160 kg
- T/480/70/11-25
- 250 kg
- T/800/70/10-25, T/1300/70/10-25
Electrical Connection2 valori
- CEE-Connector, 32 A
- T/270/70/10-25
- CEE-Connector, 63 A
- T/480/70/11-25, T/800/70/10-25, T/1300/70/10-25
Cooling (air-cooled/water-cooled)2 valori
- ✓ / -
- T/270/70/10-25
- - / ✓
- T/480/70/11-25, T/800/70/10-25, T/1300/70/10-25
Range for maximum heat compensation2 valori
- 6000 ... 7500 W
- T/270/70/10-25
- 8000 W
- T/480/70/11-25, T/800/70/10-25, T/1300/70/10-25
| Specificație | T/270/70/10-25 | T/480/70/11-25 | T/800/70/10-25 | T/1300/70/10-25 |
|---|---|---|---|---|
| Testspace volume | 268 l | 494 l | 836 l | 1385 l |
| Test Space Dimensions (H x W x D) | 750 × 580 × 615 mm | 950 × 800 × 650 mm | 950 × 1100 × 800 mm | 950 × 1100 × 1325 mm |
| External Dimensions (HxWxD) | 1950 × 895 × 2322 mm | 2090 × 1115 × 2605 mm | 2118 × 1415 × 2810 mm | 2118 × 1415 × 3335 mm |
| Total load | 140 kg | 160 kg | 250 kg | |
| Electrical Connection | CEE-Connector, 32 A | CEE-Connector, 63 A | ||
| Cooling (air-cooled/water-cooled) | ✓ / - | - / ✓ | ||
| Range for maximum heat compensation | 6000 ... 7500 W | 8000 W | ||
| Voltage Rating | 3/N/PE AC 400 V ±10 % 50 Hz | |||
| Refrigerant (main/pre-cooling) | R449A / R23 (R469A) | |||
| Temperature range | -70 … 180 °C | |||
| Range for temperature change rate | 10 ... 25 K/min | |||
Valoare comună modelelor peste care se întinde