Trigger output interface, ES 500-RTA6
Trigger output interface for ALMEMO® 510 V7 data acquisition systems.
Technical data and functions
- Universal trigger output interface for ALMEMO® 510 V7 data acquisition systems, controlled from the CPU slot via internal SPI bus.
- Up to 4 RTA6 plug-in units are supported per ALMEMO® 510.
- Up to 10 peripheral elements (relays, trigger inputs, analog outputs), each with individually configurable function.
- Relay functions, total alarm, assignment to particular limit values, or addressing via interface, with inverse relay addressing for alarm in the event of power failure and relay states shown via LEDs.
- Watchdog function in the event of a failure of ALMEMO® device or computer addressing.
- Either 2 or 4 analog outputs (10 V or 20 mA programmable, 16 bit DAC, electrically isolated) can be assigned to any measuring channels, scalable sub-areas, or alternatively addressing via interface.
- Basic version with 2 trigger inputs (optocoupler 4 to 30 V) and 4 normally open semiconductor relays (50 V, 0.5 A).
- Connection of peripherals via ALMEMO® clamp connectors, with power supply via the ALMEMO® system.