Sari la conținut
Bumbas Electric

Automatic memory readout1 / 8

Automatic memory readout

WinControl data and monitoring functions

Add-on modules for AMR WinControl for reading out and saving measured data, monitoring and alarms, password and copy protection, test benches, long-term monitoring and video recording.

These modules extend the AMR WinControl measurement software. Each one has its own datasheet in the documents below.

Automatic memory readout

Requirement: WinControl measurement software.

  • This module greatly facilitates the task of reading out from the device memory of an autonomous data logger.
  • Saving data to the data logger is interrupted, its memory is read out, and, if this is successful, the memory content is deleted. The time-of-day is synchronized and saving data to the data logger is resumed.
  • Reading out from memory can be completely automated in the form of schedules.
  • All steps and possible errors are documented in the events list.

Automatic saving-to-memory

Requirement: WinControl measurement software.

  • Measured data can be saved to memory - manually or on a time-controlled or event-driven basis.
  • Not only daily / weekly / monthly files can be specified but also files with any random periods of time.
  • Data is saved to memory automatically in the background - irrespective of any opened diagrams, tables, or displays.
  • Measured value files can be exported automatically on completion of a save-to-memory cycle and be sent by e-mail (as an option with the events list).

Monitoring Functions

Requirement: WinControl measurement software.

  • An alarm can be triggered by a component failure or a limit value infringement.
  • Alarm processing can be activated individually for each measuring point.
  • Alarms are reported visually and / or acoustically.
  • The cause and the duration of events responsible for triggering the alarm are documented in an events list.
  • Alarm reports can be confirmed either individually or all together.
  • If the cause of an alarm persists uncorrected an alarm reminder is issued to ensure that the alarm is not forgotten after it has been confirmed.
  • A line graph with settable history can be generated for the variable triggering an alarm.
  • In the event of an alarm being triggered e-mails can be sent, ALMEMO® output relays can be switched, and programs or scripts can be executed.
  • Alarm reports can be forwarded via the network.
  • In the event of a limit value being infringed program control commands can be executed (KwikScript).

Password protection

Requirement: WinControl measurement software.

  • Thanks to the integrated user management system, unauthorized access to AMR WinControl is impossible. This policy reduces the security risks to a minimum.
  • Every change of user is logged in the events list for subsequent evaluation.
  • Access rights can be defined individually per user or can be copied.
  • Authentication can be done as WinControl user or Windows user (local or Active Directory). Windows groups are supported.
  • Access limitations can be defined for every single program feature.
  • Alarm confirmations can be assigned unequivocally to particular users.
  • The password protection is the minimum requirement for the system validation according to FDA 21 CFR Part 11.

Copy protection

Requirement: WinControl measurement software, USB dongle.

  • AMR WinControl incorporates a copy protection system which requires a PC-dependent code to enable it. To receive this code the user must first register the software by telephone, fax, or e-mail. Per licence purchased the software may be installed and operated on one computer.
  • It is also possible as an option to request a hardware copy protection mechanism, a dongle; with this the software can be installed on any number of computers but will only run on that PC into which the dongle is currently plugged.
  • With the akrobit® license server, it is possible to run the software on as many computers in the company network as licenses have been purchased, without the need for cumbersome replugging. The license is assigned dynamically when the software is started and closed. No additional USB dongle is required.

Test bench manager

Requirement: WinControl measurement software and additional module „Automatic saving-to-memory“.

  • Several autosave managers can be operated and organized via a convenient, easy-to-use graphical user interface.
  • Measured data can thus be saved simultaneously to different files.
  • Autosave managers can be started and stopped independently of one another and according to various criteria (time-driven or event-driven).
  • Different measuring locations (operating in parallel) can thus be treated separately.
  • Measured value files can be indicated as write-protected already during recording.
  • Including 10 autosave managers (optionally more available)
  • If required, we offer to implement individual automations of test stations including input of test parameters, test procedure, signaling (optical/acoustic), and protocol printout.

Long-term / continuous monitoring

This package, based on the AMR WinControl “professional” version, contains all the options and modules needed to implement long-term and continuous monitoring of critical measurable variables.

  • Integrated user management with individually settable access rights and password protection
  • Tamper-proof event list with sort and filter functions
  • Trend monitoring - pre-alarm for signaling trend developments
  • Signaling of alarms and events with user-specific confirmation and comments
  • Alarm confirmation per web server (authentication and SSL / TLS available)
  • Schedules: Automatic switching ON / OFF of alarm treatment for each measuring point, e.g. alarm treatment on working days between 6 and 18 o’clock only.
  • Temporarily withdrawing certain measuring points from alarm treatment, e.g. for defrosting a cold room
  • In the event of alarm an MS-Excel log can be printed out automatically. Users can modify the log provided or create their own.
  • Failsafe: Automatic reading out of the device memory after loss of connection to the device. Requirements: ALMEMO® device with failsafe mode and internal memory
  • System configuration
  • Integrity check on all measuring points and measuring instruments after program start
  • Processing of measured and calculated variables in control and regulation functions
  • Automatic printout and / or e-mail with daily files and event lists
  • Including security package.

Security package

  • Data security: Automatic backup of all automatically recorded data (daily and weekly files, measured values recorded on an event-controlled basis, event lists, etc.)
  • Fail-safe: In the event of failure a watchdog is triggered for PC restart and / or signaling via relay.
  • Including watchdog card

PIMEX: combined measured value recording and video recording

Requirement: WinControl 3 or WinControl 4.

  • Simultaneous acquisition of measured values from ALMEMO® devices together with video data from a digital source
  • The measured data and video signal are synchronized and displayed together.
  • The modes available are preview, record, and playback.
  • PIMEX player is included in the professional version (WC3). The recording function is available as a module.
  • Possible applications: Documentation / visualization of the process environment (e.g. for safety in the workplace, quality management, etc.)