Sari la conținut
Bumbas Electric

Thermal transmittance (U) wizard1 / 9

Thermal transmittance (U) wizard

WinControl wizards

Add-on wizards for AMR WinControl: thermal transmittance, comfort index, thermal quantity, A0/F0 value, refrigerant, sensor and climate chamber calibration, process sequences and extended evaluation.

These modules extend the AMR WinControl measurement software. Each one has its own datasheet in the documents below.

Thermal transmittance (U) wizard

Requirement: WinControl measurement software.

  • The thermal transmittance (U) wizard is available for Online and Offline calculations; it guides the user through all the required steps.
  • The user can choose from a selection of calculation methods - for the experimental thermal transmittance value, for the thermal transmittance value according to DIN 4108, and for the official calculated value.
  • Determination of the currently calculated value and the sliding average value.
  • The calculation methods will be described and the allocation of the corresponding measuring variables will be provided.
  • After completing all steps a line diagram will be created, which will then be filled with the measuring data and the calculated variables.
  • The cursor function can be used to open the statistic table, which provides further evaluation options.

PPD / PMV wizard for comfort index measurement

Requirement: WinControl measurement software.

  • Calculation of thermal comfort as per DIN 1946 Part 2 and ISO 7730
  • User guidance by means of a wizard and easy-to-understand evaluation
  • Output in the form of “predicted mean vote” (PMV) and “predicted percent of dissatisfied” (PPD)
  • Online and offline calculation of PMV and PPD in real time or on the basis of measured values already existing
  • Graphical representation of measured data and calculated values in a format suitable for export (e.g. ASCII, MS Excel, DiaDEM, etc.)
  • Calculation parameters can be saved as a model for subsequent calculations.
  • Additional PMV / PPD functions are available for use in arithmetic channels.

Thermal quantity wizard

Requirement: WinControl measurement software.

  • The thermal quantity is calculated automatically from the volume flow and the temperature difference.
  • You can enter settings easily and conveniently using the wizard.
  • Data tables for water are included in delivery; users can define their own extensions for other media themselves.
  • The thermal quantity can be calculated in real time or on the basis of existing measured value files.

Assistant for A0/F0 value

Requirement: WinControl measurement software.

  • Calculation of the A0 or F0 value during sterilization in AMR WinControl.
  • Wizard for creating the appropriate calculation channels with specification of the temperature measuring points, the reference temperature and the z-value.
  • Any number of independent calculations in parallel.
  • Calculations can be performed live (online) or subsequently for recorded values.

Assistant for refrigerant

Requirement: WinControl measurement software.

  • Calculations of dew point or boiling temperature.
  • Wizard for creating the appropriate calculation channels with specification of pressure measuring points and data tables for desired refrigerant.
  • Refrigerants can be added by the user.
  • Any number of independent calculations in parallel.
  • Calculations can be performed live (online) or afterwards.

Assistant for calibrating measuring sensors

Requirement: WinControl 3 or WinControl 4.

  • Multilevel calibration via self-defined calibration programs with set point lists and stability criterion
  • Hardware profile with set point, reference and calibration measuring points.
  • Automated procedure with measured value recording
  • Drive a calibrator (set point specification)
  • Any desired number of measuring points can be calibrated simultaneously
  • Saving the values as AMR, CSV or Excel file
  • Saving a configurable number of values per calibration step in case the stability criterion is met
  • Overview window with progress bar
  • The price for the module depends on the number of calibration stations and calibrators that are to be supported simultaneously.

Assistant for the calibration of climate chambers

Requirement: WinControl 3 or WinControl 4.

  • Calibration according to guideline DAkkS-DKD-R 5-7
  • Support of methods A and B with 9 and more measuring points
  • Fully automatic calibration over any number of temperature and humidity steps with stability criterion
  • Direct integration of climate chambers (Weiss/Vötsch, CTS, Memmert, Binder, ESPEC, ATT and Feutron) for setpoint specification and measured value recording
  • Online visualization of the calibration process for all measuring points
  • Calculation of the local humidity at the temperature measuring points, taking air pressure and dew point into account
  • Additional support for dew point mirrors from MBW, DewMaster, DewTrans and Michell
  • Automatic creation of a complete Excel report with all measured values, measurement uncertainties and measurement uncertainty budgets
  • Excel report template can be easily customized by the user to suit their needs

Assistant for process sequence and setpoint generator

Requirement: WinControl 3 or WinControl 4.

  • Creation of time-controlled value and switching sequences via a graphical user interface.
  • Tabular specification of times and values with repetitions
  • Continuous progressions (ramps) as well as abrupt changes of values
  • Waiting for signals
  • Representation of the total course in a line diagram
  • Parallel operation of several process sequences
  • Support for all ALMEMO® analog and relay outputs, as well as supported third-party devices with setpoint specification such as climatic chambers and furnaces.

Extended evaluation functions

Requirement: WinControl measurement software.

  • Measured value files can be incorporated in new or already existing line charts in the form of comparative characteristics.
  • Folders containing a large number of measured value files can be conveniently grouped using various patterns based on file names and filters according to time and measuring point.
  • Local maximum and minimum values can be shown in a line chart as any measured value curve required. The search radius between maximum and minimum can be freely set.